- SICO Fold & Set Entertainment Stage 60x40 with 16x16 Soundwings at 4, 5, or 6 feet, 2 full height stairways,Carpeted or Black Tuff Deck
- Fold & Roll, 8 pieces @ 6' x 8', height is 16", 24" or 34”
- Carpeted or Black Tuff Deck
- Black Skirting is available for all staging
Dance Floor
- 64 sections of 4’ X 4’ portable parquet flooring (32’ X 32’)
- 90,000 lbs roof capacity
- 30’ x 30’ bays
- 8,000 lbs per node
- 2,500 lbs vertical load at mid-span
- 400 lbs lateral load at mid-span
- Height to low steel: 70'
- Height to high steel: 85'
- Steel I-beam Roof Construction
- Catwalk (can be rigged from)
- Main Speaker Cluster and Center Hung Scoreboard can be obstructive to rigging. Located over the center of the arena floor
Forklift
- 1 Clark, propane, max. capacity 4,800 lbs., 60” Fork Extensions
- 16 pieces at 5' x 8'
- 27 "bicycle" barricades @ 3' x 8'
- Acoustically Engineered Fully Digital System
- Yamaha M7CL32 Permanent Console FOH
- Yamaha LS9 24 Input Portable Console
- 2 Permanent Electro-Voice XLC-127 Bi-Amped 5 Piece Arrays (East & West)
- 2 Permanent Electro-Voice XLC-127 Bi-Amped 6 Piece Arrays (North & South)
- 12 Permanent Electro-Voice Xi-2181AF Dual EVX-180B 18" Low Frequency Drivers
- 2 Portable Electro-Voice XLD281 Bi-Amped 8 Piece Arrays (Rigged North or West)
- 6 Portable Electro-Voice Xi-2181A Dual EVX-180B 18" Low Frequency Drivers
- 8 Portable Electro-Voice QRx-112/75 Loudspeakers
- All Drivers Powered by QSC Amplifiers with QSControl FOH
- 8 Shure Beta 87c Wireless Microphones
- Various Microphones, Powered Speakers, and Cabling
- Intercom
- Clear-Com 2 Channel System with 10 Headsets and Belt Packs
- 64 Phillips 1800W HID Floods for Arena Floor
- Quartz House and Aisle Lights -- Dimmable, All Controlled Front of House
- Spotlights
- 2 1.2K Lycian 1290XLT Xenon Spotlights
- 2 1275 Lycian Superstars with HMI Lamp available
- All power is lugged 5 wire 3 phase 208VAC Production,all located USR, 120’ from USC
- Lighting
- 1 @ 400 amps
- 1 @ 600 amps
- 2 @ 200 amps
- Sound
- 1 @ 200 amps
- 1 @ 100 amps
- Supplemental Power (please confirm with Facility if you require these services):
- 1 @ 800 amps, located USL, 120’ USC
- 1 @ 400 amps, located on catwalk USC
- 4 @ 200 amps, located on truck ramp
- Housekeeping – In-House Staff
- Contracted Event Clean-up
- Stagehands
- Riggers - IATSE
- Lighting - In-House Staff
- Sound - In-House Staff
- Note: Breaks, meal penalties or overtime may apply when using union labor. Halton Arena is a right-to-work venue.
- Adjacent Parking Lot (Two parking decks and multiple surface lots nearby)
- Loading door: 20'h x 16'w
- Truck Loading
- Single loading bay at dock-level
- Ramp access to facility for street-level loading